b'HVT-3 SERIESHVT-3 SERIESTORQUESTorque Values (Nm) - Reinforced Filled PTFE SeatsLine Pressure MPAValve Size 1 2 3 4 5 7 9 10.3 Stem Maximum mm Torque (Nm)8, 10, 15 6 6 6 6 6 6 7 8 2620 8 8 8 8 9 10 10 12 2625 12 12 12 13 14 16 16 19 7532 17 17 17 18 19 22 28 30 8540 22 22 22 24 25 27 33 35 8550 32 32 32 34 36 40 46 48 8565 45 55 65 75 90 25080 110 130 144 160 170 390Consult us for higher pressures.When conditions below apply, then calculate torque using the following application factors:Frequency of OperationService ConditionsLess than once per week+28%Light slurry semi solids+40%Less than once per week+40%Heavy slurry and some solids+75%Less than once per year+60%Temperature - Minus 40C to minus 20C+75%Minus 20C to 0C+25%Cv FACTORSize Cv Factormm gpm8 710 815 1120 3025 5032 8040 13050 27080 400 Actuated Version (APV)AS 4617Limit Switch Box Option Deadman Lever Option Deadman DoubleLever Option12 SUPERSEAL - Industrial Ball Valves'